BSQTS - H/S EPOXY MASTIC ACTIVATOR, VF-525
- MSDS: BSQTS
- Manufacturer: EI DUPONT DE NEMOURS AND CO INC
- Product Name: H/S EPOXY MASTIC ACTIVATOR, VF-525
- National Stock Number: 8010-00N041541
Product Identification
Product ID:H/S EPOXY MASTIC ACTIVATOR, VF-525
MSDS Date:01/22/1991
FSC:8010
NIIN:00N041541
MSDS Number: BSQTS
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: EO716
Contractor
Telephone: (800) 441-7515
Cage: EO716
Ingredients
OCCUP CHEM REPROD HAZ. SEEK CONSULTATION FROM APPROP
RTECS: 9999999ZZ
SAFE HANDLING AND EXPOSURE INFORMATION .
RTECS: 9999999ZZ
TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (HYDROUS
CAS: 14807-96-6
RTECS: WW2710000
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST
EPICHLOROHYDRIN BISPHENOL A; (BISPHENOL-EPICHLOROHYDRIN
CAS: 25068-38-6
RTECS: SL6475000
PHENOL FORMALDEHYDE RESIN; (PHENOLIC POLYMER)
CAS: 9003-35-4
5@20C
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: 3%
OSHA PEL 50 PPM, C, S
ACGIH TLV: 50 PPM, C, S
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
TOLUENE
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 10%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ACETIC ACID, ETHYL ESTER; (ETHYL ACETATE)
CAS: 141-78-6
RTECS: AH5425000
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
THEORETICAL 2.06
RTECS: 9999999VO
EXHIBITED HIGH FREQ HEARING DEFICITS.
RTECS: 9999999ZZ
HIGH EXPOS OF LAB ANIMALS RSLTD IN SECONDARY ANEMIA
RTECS: 9999999ZZ
CLOUDY SWELLING & AN EXCESS OF BLOOD IN VARIOUS
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: MAY CAUSE NOSE & THROAT IRRIT.
MAY CAUSE NERV SYS DEPRESS CHARACT BY FOLLOWING PROGRESSIVE STEPS:
HDCH, DIZZ, NAUS, STAGGER GAIT, CONFUSN, UNCON. RPTS HAVE ASSOC
RPTD & PRLNGD OVEREXP TO SOLV W /PERM BRAIN & NERV SYS DAM.
SKIN/EYE CONT: MAY CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ
CONT (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: MAY CAUSE SKIN IRRIT W/DISCOMFORT &
DERM. ING 1: RPTD & PRLNGD OVEREXP TO TALC MAY LEAD TO TYPICAL
X-RAY CHANGES & CHRONIC LUNG DISEASE. ING 2: RPTD EXPOS MAY CAUSE
ALLERGIC SKIN RASH, ITCH, SWELLING. ING 4: LIQ SPLASHES IN EYE MAY
RLST IN CHEM BURNS. MAY CAUSE ABNORM BLOOD FORMING FUNC W/ANEMIA.
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP,
PREF MOUTH-TO-MOUTH. IF BRTHG DFCLTY PERSISTS, OR OCCURS LATER,
CONSULT A PHYS. EYE: IMMED FLUSH WITH PLENTY OF WATER FOR @ LST 15
MIN; CALL A PHYS. SKIN: WASH W/SOAP & WATER. IF IRRIT OCCURS, CONT
A PHYS. INGEST: CALL A PHYS IMMED & HAVE NAMES OF INGRED AVAIL.
Fire Fighting
Flash Point Method:CC
Flash Point:>20F,>-6.7C
Lower Limits:1%
Upper Limits:13.1%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO PREVENT PRESSURE
BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FL PT, EMITS FLAMMABLE
VAPORS WHICH, WHEN MIXED WITH AIR, CAN BURN/BE EXPLOSIVE. FINE
MISTS/SPRAYS MAY BE FLAMM @ TEMPS BELOW FL PT.
Accidental Release
Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNIT. PREVENT
SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LBL PREC. KEEP AWAY FROM HEAT,
SPARKS & FLAME. CLOSE CONTR AFTER EACH USE. GROUND ALL CONTRS WHEN
POURING. DO NOT STORE ABOVE 120F.
Other Precautions:DO NOT SAND, FLAME CUT, BRAZE/WELD DRY COATING W/OUT
A NIOSH/MSHA APPROVED RESPIRATOR OR APPROPRIATE VENTILATION.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR A PROPERLY
FITTED VAP/PARTICULATE RESP APPRVD BY NIOSH/MSHA (TC-23C) FOR USE
W/PAINTS DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS ARE
EXHAUSTED. FOLLOW RESP MFR'S D IRECTION FOR RESPIRATOR USE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOL & PATTERN TO KEEP CONTAM
BELOW APPLIC OSHA REQUIREMENTSS & OTHER SUGGESTED EXPOS LIM.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment:COVERALLS.
Work Hygienic Practices:PROTECTIVE CREAMS: DO NOT USE FOR PROTECTION,
MAY BE USED FOR EASE OF CLEAN UP.
Supplemental Safety and Health
EFTS OF OVEREXP: RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY.
CAN BE ABSORBED THRU SKIN IN HARMFUL AMTS. ING 5: RECURRENT OVEREXP
MAY RSLT IN LIVER & KIDNEY DAM. HIGH AIRBORNE LEVELS HAVE PRDC D
IRREG HEART BEATS IN ANIMALS & OCCAS PALPITATIONS IN HUMANS. RATS
EXPOSED TO VERY HIGH AIRBORNE LEVELS HAVE (ING 8)
Chemical Properties
Boiling Pt:B.P. Text:>169F,>76C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.28
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:MODERATE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:28.3
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE, OXIDES OF HEAVY METALS REPORTED IN INGREDIENTS.
Disposal
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.